The ADAS1000 measures electro cardiac (ECG) signals, thoracic impedance, pacing artifacts, lead on/off status and outputs this information in the form of a data frame supplying either Lead/Vector or Electrode data at programmable data rates. Its low power and small size make it suitable for portable, battery powered applications. The high performance also makes it suitable for higher end diagnostic machines.
The ADAS1000 is designed to simplify the task of acquiring and ensuring quality ECG signals. Value-added cardiac postprocessing is executed externally on a DSP, microprocessor or FPGA. Several digital output options ensure flexibility when monitoring and analyzing signals. The ADAS100
0 provides a low power, small data acquisition system for biopotential applications.
Auxiliary features that aid in better quality ECG signal acquisition include: multi-channel averaged driven lead, selectable reference drive, fast over load recovery, flexible respiration circuitry returning magnitude and phase information, internal pace detection algorithm operating on 3 leads and option of AC or DC leads off detection.
Since ECG systems span different applications, the ADAS1000 features a flexible power/noise scaling architecture where the noise can be reduced at the expense of increasing power consumption. Signal acquisition channels may be shutdown to save power. Data rates can be reduced to save power.
To ease manufacturing tests, development, as well as offer holistic power-up testing, the ADAS1000 offers a suite of dc and ac test excitation via the CAL DAC, CRC redundancy testing in addition to read-back of all relevant register address space.
The ADAS1000 is available in two package options, either a 56 lead LFCSP or a 64 lead LQFP package and is specified over -40°C to +85°C temperature range. The ADAS1000 is a full featured 5 channel ECG including respiration and pace detection, while the ADAS1000-1 offers only ECG channels with no respiration or pace features. Similarly the ADAS1000-2 is a subset of the main device and is configured for gang purposes with only ECG channels enabled (no respiration, pace, RLD, etc).
These terms and conditions are for reference only. The actual terms and conditions are subject to the sales staff's quotation.
- Please check the technical specifications of the products when ordering.
- MOQ is the minimum order quantity required to purchase each part.
- If you have special ordering instructions, please indicate them on the order page.
- Pre-Shipment Inspection (PSI) will be used when ordering.
- You can check the status of your order in the “My Order” section of your personal account.
- Orders cannot be canceled after the package has been shipped.
View more >
- Works with both individual and corporate clients. View more >
- All prices on the website include 22% VAT.
- Invoices are issued in the currency specified, but payment is made in Russian rubles at the exchange rate on the day of payment.
- If you need a detailed invoice or a tax identifier, please contact us.
- Delivery will take between 1 to 2 weeks after the shipment is sent to your country.
- Your order will be processed only after the invoice has been paid.
- The tracking number will be sent to you after the order is shipped. (It may take up to 24 hours for the information to be available from the carrier.) View more >
- Carefully tested and packaged by ChipWorker- Vacuum packed - Anti-static packaging - Anti-vibration foam
- Income quality control (IQC), 800+ qualified distributors.
- Authorities test the chip to ensure the quality, authenticity and safety of your device.
- Decapsulation control
- X-ray inspection
- XRF inspection
- Electrical testing
- Surface testing
Contact Us
Contact us today and a sales representative will provide you with a quote for any model.
Customer Service, Quick Links
Find immediate assistance and access to our most used services through our Quick Links. Your satisfaction is our priority.